ADDITIONAL INFORMATION:
Samson digital control valves are used at the end of the hose assembly for measured dispensing lubricants and anitfreeze solutions.
Fluids Handled
- Synthetic and mineral based oil
- Gear Oil
- Hydraulic oil and fluids
- ATF
- Antifreeze solutions
• Extensively and rigorously field tested. Reliable performance.
• High precision machined measuring chamber with tight tolerances, quality gears and stainless steel shafts eliminate the need of calibration to adjust for fluid viscosity.
• Sealed battery compartment and isolated electronic register for extended life.
• Easy to read large character display, with batch, trip (resettable totalizer) and totalizer functions.
• Rough TPE boot surrounds the entire meter for even greater durability.
• Replaceable AAA batteries.
Maximum Free Flow Rate
8 gal/min (30 l/min)
Maximum Working Pressure
1,450 psi (100 bar)
Fluid Inlet
1/2" NPTF
Fluid Outlet
1/2" NPTF
Accuracy
+/- 0.5%
Power Source
2x "AAA" 1.5 Batteries
Wetted Materials
Acetal, Aluminium, Stainless Steel, NBR, Zinc Plated Steel, TPU, Polyamide