Alemite oil mist systems are used to service all types of machine elements that require continuous lubrication, such as rolling element bearings and chain drives. These reliable systems have no moving parts, deliver a constant, measured stream of clean, atomized oil and are a cost-effective option for ongoing automatic lubrication.

OIL-MIST GENERATORS

Alemite Oil-Mist Generators provide lubrication for multiple lubrication points or machines.

HIGH CAPACITY OIL-MIST GENERATORS

FEATURES:

• 3.6 gallon oil reservoir

• Low oil level float switch

• Mist pressure switch (high & low)

• Oil level sight glass

• Air pressure gauge

• Mist pressure gauge

• Oil temperature gauge

 

OPTIONAL ACCESSORIES

• Alarm annunciator (387275)

- Required to provide visual/audible alarm signals

• Automatic oil refill kit (385789)

- Includes 3-float float switch and in-line oil filter

- Refill kit also requires oil solenoid valve

  115 V (383647-1)

  230 V (387449)

• Automatic refill pump package (388415)

- Includes 1:1 ratio air-driven pump with accessories including filter/regulator, 7 ft long hose and valves designed for use with 55 gallon oil drums.

Product # CFM Nominal Flow Range No of nozzles Mist outlet Voltage
3725-A6 9.7 3.5 - 16.5 CFM 1 2-1/2" NPTF(f) 120 V AC, 60/50 HZ
3720-A6 13 5.2 - 21 CFM 1 2-1/2" NPTF(f) 120 V AC, 60/50 HZ
3721-A6 21 7.5 - 33 CFM 1 2-1/2" NPTF(f) 120 V AC, 60/50 HZ
3722-A6 41 15 - 45 CFM 2 2-1/2" NPTF(f) 120 V AC, 60/50 HZ
3726-A6 65 31 - 73 CFM 2 3" NPTF(f) 120 V AC, 60/50 HZ
3720-B6 13 5.2 - 21 CFM 1 2-1/2" NPTF(f) 240 V AC, 60/50 HZ
3721-B6 21 7.5 - 33 CFM 1 2-1/2" NPTF(f) 240 V AC, 60/50 HZ
3722-B6 41 15 - 45 CFM 2 2-1/2" NPTF(f) 240 V AC, 60/50 HZ
3726-B6 65 31 - 73 CFM 2 3" NPTF(f) 240 V AC, 60/50 HZ


 

HIGH CAPACITY OIL-MIST GENERATORS WITH AIR HEATER

FEATURES:

• Thermo-Aire® air heater

• 3.6 gallon oil reservoir

• Low oil level float switch

• Mist pressure switch (high & low)

• Oil level sight glass

• Air pressure gauge

• Mist pressure gauge

• Oil temperature gauge

• Air temperature gauge

 

OPTIONAL ACCESSORIES

• Alarm annunciator (387275) - Required to provide visual/audible alarm signals.

• Automatic oil refill kit (385789) - Includes 3-float float switch and inline oil filter. - Refill kit also requires oil solenoid valve 115 V (383647-1) 230 V (387449)

• Automatic refill pump package (388415) - Includes 1:1 ratio air-driven pump with accessories including filter/regulator, 7 ft long hose and valves designed for use with 55 gallon oil drums.

 

Product #

CFM nominal

Flow range

No. of nozzles

Mist outlet

Voltage solenoid and oil heater

Voltage air heater

3730-RW6

13

5.2 - 21

1

2-1/2" NPTF(f)

120 V AC, 60/50 Hz

240 V AC, 60/50 Hz

3731-RW6

21

7.5 - 33

1

2-1/2" NPTF(f)

120 V AC, 60/50 Hz

240 V AC, 60/50 Hz

3732-RW6

41

15 - 45

2

2-1/2" NPTF(f)

120 V AC, 60/50 Hz

240 V AC, 60/50 Hz

3736-RW6

65

31 - 73

2

3" NPTF(f)

120 V AC, 60/50 Hz

240 V AC, 60/50 Hz

3730-BW6

13

5.2 - 21

1

2-1/2" NPTF(f)

240 V AC, 60/50 Hz

240 V AC, 60/50 Hz

3731-BW6

21

7.5 - 33

1

2-1/2" NPTF(f)

240 V AC, 60/50 Hz

240 V AC, 60/50 Hz

3732-BW6

41

15 - 45

2

2-1/2" NPTF(f)

240 V AC, 60/50 Hz

240 V AC, 60/50 Hz

3736-BW6

65

31 - 73

2

3" NPTF(f)

240 V AC, 60/50 Hz

240 V AC, 60/50 Hz