Alemite oil mist systems are used to service all types of machine elements that require continuous lubrication, such as rolling element bearings and chain drives. These reliable systems have no moving parts, deliver a constant, measured stream of clean, atomized oil and are a cost-effective option for ongoing automatic lubrication.
OIL-MIST SYSTEM COMPONENTS
APPLICATION RECLASSIFIER FITTINGS
Reclassifier fittings perform two critical functions:
• They maintain consistent system mist pressure for all lubrication points
• They deliver a measured amount of mist flow to each point, as determined by their orifice size
Every lubrication point requires a reclassifier fitting.
Since oil-mist can be applied to a wide array of machine elements (bearings, gears, chains, etc), Alemite offers four different types of fittings. Each type provides a different degree of reclassification of the dry mist into a suitable degree of wetness to adequately lubricate the element.
SPRAY FITTINGS
Compared with mist fittings, spray fittings convert a greater percentage of mist into a wetter spray. Primarily used to lubricate chain, gear teeth and slow-moving equipment. Can also be used to apply a thin oil film on surfaces. Chiselpoint tip should be located within 1/2" to 1" of surface to be lubricated. Fittings have black zinc finish.
Inlet |
Inlet |
Orifice (baffled) |
CFM @ 20 in. H20 |
||
Outlet |
Outlet |
Diameter |
Length |
Flow area |
|
381288-1 |
0.024" |
1.38" |
0.000452 |
0.03 |
|
381283-2 |
381288-2 |
0.035" |
1.38" |
0.000962 |
0.05 |
381283-3 |
381288-3 |
0.042" |
1.38" |
0.00138 |
0.07 |
381283-5 |
381288-5 |
0.055" |
1.38" |
0.00237 |
0.16 |
381283-8 |
381288-8 |
0.067" |
1.38" |
0.00352 |
0.30 |