Skip to content
Free Shipping on All Orders
Free Shipping on All Orders

Country

The Beckett GeniSys™ Advanced Burner Control is a 120 VAC primary safety control for Commercial / Industrial pressure washer and other industrial applications. The GeniSys™ is used with a suitable cad cell flame sensor to control the oil burner motor, igniter, and optional solenoid valve. It has 24 VAC thermostat terminals (if applicable) compatible with mechanical and many other thermostats. It can provide interrupted or intermittent duty ignition, and it has a 15 second lockout time.

Features & Benefits

  • Epoxy potted for moisture resistance
  • Compatible with most operating controls
  • Customizable pre-time and post-time
  • Three status lights for system monitoring and diagnostics
  • Welded relay protection with redundant motor relays
  • Limited reset and limited recycle
  • Sleek, modern design
  • Technician pump prime mode
  • 18 month warranty
  • Communication ports for the contractor tool
Inputs
  • Voltage: 102-132 VAC
  • Current: 150 mA plus burner motor, igniter, and valve loads
  • Frequency: 60 Hz
Outputs
  • Motor: 120 VAC, 10 full load amps (FLA*), 60 locked rotor amps (LRA) Note: Reduce motor FLA rating by igniter current
  • Igniter: 120 VAC, 3 A @ 0.7 PF min
  • Solenoid Valve: 120 VAC, 1 A @ 0.7 PF min
  • Thermostat Anticipator Current: 0.1 A (if applicable)
  • Thermostat Voltage: 24 VAC (if applicable)