Skip to content
Free Shipping on All Orders
Free Shipping on All Orders

Country

The Beckett GeniSy™ 12 V Advanced Burner Control is a 12 VDC primary safety control for oil burners used on pressure washers, road stripers, crack sealers, hot patchers, and asphalt distributors, to name a few examples. The GeniSys™ 12 V is used with a suitable cad cell flame sensor to control the oil burner motor, igniter, and optional solenoid valve. It can provide interrupted or intermittent duty ignition, and it has a 15 second lockout time.

Features & Benefits

  • New Feature Programmable valve-on delay and motor-off delay provides chamber cooling after call for heat
  • Valve-on delay / motor-off delay (Field programmable with Beckett’s Contractor Tool)
  • Epoxy potted for moisture resistance
  • Welded relay protection with redundant motor relays
  • High ambient temperature rating
  • Alarm output enables visual or audio indication of flame failure and lock out condition
  • Interrupted ignition
  • Relight function
  • Fused protection
  • 15 second lockout time
  • Communication port

Technical Information Bulletins

GeniSys Contractor Tool Lockout Tech Bulletin

Inputs
  • Voltage: 12 VDC nominal (11 to 16 VDC)
  • Current: 160 mA nominal (500 mA max at 16 VDC)
  • Enable Load: 40mA at 12 VDC
Outputs
  • Motor: 12 VDC, 20 full load amps (FLA), 100 locked rotor amps (LRA)
  • Igniter: 12 VDC, 5 A
  • Solenoid Valve: 12 VDC, 2 A
  • Lockout Alarm: 12 VDC, 2 A
Environmental Ratings
  • Storage & Operating Ambient Temperature: -40°F to +160°F (-40°C to +71°C)
  • Moisture: 5-95% RH, condensing

GeniSys 12V Model Guide

1 Replaces the Beckett 7434 control.
2 Valve-on delay and motor-off delay timings on all models are programmable with Beckett Contractor Tool.